Today, the majority of new roofing is a white single-ply membrane, either TPO (thermoplastic polyolefin) or PVC (polyvinyl chloride). This is due mostly to new energy codes that require reflective roofing to reduce heat absorption into the structure. Over the past several years we have investigated moisture build-up and damage to building materials occurring underneath […]
Read More →Problem No. 101 – Moisture Intrusion at Stucco Accessories in Corners and at Intersections
on January 10, 2014in Blog
Design Problem We have observed numerous leakage problems in stucco cladding from poorly field fabricated metal accessories. Recommended solution: Specify pre-fabricated, shop-welded intersection and corners. This will make field installations much faster and should eliminate leaks through voids and seams in the metal. One resource; www.stocktonproducts.com
Read More →